Sim2 C3X1080 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Projektory Sim2 C3X1080. C3X1080 Control Specs 1.1 Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 14
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
SIM2 Multimedia
C3X1080
RS-232C CONTROL SPECIFICATIONS
Rev. 1.1 (30 January 2008)
Przeglądanie stron 0
1 2 3 4 5 6 ... 13 14

Podsumowanie treści

Strona 1 - SIM2 Multimedia

SIM2 MultimediaC3X1080RS-232C CONTROL SPECIFICATIONSRev. 1.1 (30 January 2008)

Strona 2 - Contents

2.3 Status CommandsStatus Commands may be used to get the current value of the main projector parameters.Status CommandsParameter CommandProjector Sta

Strona 3 - 1 Introduction

• Bytes 23 and 24 (labeled FF FF in the table above) contain the Failure Condition (if any):OK (No failure) 00 00Lamp Failure 00 01Fan Failure (Lamp C

Strona 4 - 1.2 Execution of the command

Lamp StatusWhen then unit is On, the returned packet (27 byte long) is described in the following table:1E BE EF 10 13 00 .. .. 01 01 00 01 01 15 01 0

Strona 5 - 2 Commands

3 ExamplesSend the simulated ‘SWITCH ON FROM STANDBY’ Remote Control keycodeRemote Control allows Switching on from Standby via the key ‘0’.Send the c

Strona 6 - 2.2 Operation Commands

SIM2 Multimedia S.p.A.Viale Lino Zanussi, 11 — 33170 Pordenone — ItalyTel. +39.0434383281 — Fax [email protected] USA Inc.101

Strona 7

ContentsContents 21 Introduction 31.1 Setting up the RS-232C Serial connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.2 Execution of

Strona 8

1 IntroductionThis document describes how to interface the SIM2 C3X1080 projector with a Home Theater control system(or a PC) over a direct serial con

Strona 9

1.2 Execution of the commandCommand execution time may vary from 0.1 to 2.0 seconds, depending on the operation that have beenrequested.If the project

Strona 10 - 2.3 Status Commands

2 CommandsIn this section, serial commands (and respective responses) are listed. Commands (and responses) are seriesof bytes (numbers holding values

Strona 11 - Signal Status

Aspect Normal BE EF 02 06 00 2A F4 83 01 00 00 00 00Aspect Anamorphic BE EF 02 06 00 9D F5 84 01 00 00 00 00Aspect Letterbox BE EF 02 06 00 4C F4 85 0

Strona 12 - Lamp Status

ContrastAction Command ResponseIncrement BE EF 1A 0C 00 9D 5E 01 00 02 00 00 00 00 00 00 00 00 00 OK 20 XX 00Decrement BE EF 1A 0C 00 58 0F 01 00 03 0

Strona 13 - 3 Examples

Color Management: PrimariesAction Command ResponseSet Native BE EF 1A 0C 00 68 FE 41 00 00 00 00 00 00 00 00 00 00 00 OK 20 XX 00Set HDTV BE EF 1A 0C

Strona 14

XX is the hex representation of the value of Gamma.Example: if the returned value is XX = 04 then Gamma is set to EN5.OverscanAction Command ResponseI

Komentarze do niniejszej Instrukcji

Brak uwag