where:
Byte 7 (labeled SS in the table above) contains Projector Status:
OK 00
Power Supply Overtemperature 10
Power Supply Failure 20
If the unit is On, the returned packet (27 byte long) is described in the following table:
1E BE EF 10 13 00 .. .. 01 01 00 01 01 15 01 00 00 02 00 00 00 SS .. FF FF .. ..
0 1 17 18 20 21 23 24
where bytes marked with .. are not relevant.
The response may be separated into 4 parts:
1 bytes (byte 0) that initiates the packet (1E)
17 bytes (bytes 1-17) that duplicate the sent command (apart from 2 of them the CRC)
3 Error bytes (bytes 18-20) that signal errors in the processing of the command
4 Data bytes (bytes 21-24) that contain the requested data
If the 3 Error bytes (bytes 18-20) are 00 00 00 then requested data are valid.
The tables below explain the meaning of returned data.
Byte 21 (labeled SS in the table above) contains Projector Status:
On 01
Lamp Ignition 02
Lamp Restrike 03
Lamp Cooling 04
Bytes 23 and 24 (labeled FF FF in the table above) contain the Failure Condition (if any):
OK (No failure) 00 00
Lamp Failure 00 01
Fan Failure (Lamp Cooling) 00 02
Overtemperature (Lamp Cooling) 00 08
Front End Error 00 20
Signal Status
When then unit is On, the returned packet (25 byte long) is described in the following table:
1E BE EF 10 11 00 .. .. 01 01 00 01 01 15 01 00 00 08 00 00 00 SS .. .. II
0 1 17 18 20 21 24
where bytes marked with .. are not relevant.
The response may be separated into 4 parts: